Mobi c - Restoring natural motion to the cervical spine. The controlled mobility of the patented mobile core is the foundation of Mobi-C. With vertebrae and neck muscle movement, the Mobi-C implant is free to twist and slide left-to-right, and front-to-back, as well as rotate.

 
the mobi-c® cervical disc prosthesis is implanted using an anterior approach. patients should have failed at least 6 weeks of conservative treatment or demonstrated progressive signs or symptoms despite nonoperative treatment prior to implantation of the mobic® cervical disc prosthesis. approval order: approval order: summary. Listi..

Sep 27, 2019 · Mobi-C group composed of 15 subjects, in which 6 were male and 9 were female. There were no statistical differences in demographics and baseline characteristics of subjects between the M6-C and Mobi-C groups, including age, gender, BMI, smoking history, the type of surgery, ROM and FSU height ( Table 7 ). Jan 31, 2023 · The Mobi-C Cervical Disc. ZimVie Inc. has marked a major milestone with its Mobi-C Cervical Disc, announcing that more than 200,000 discs have been implanted worldwide. The total includes patients treated in more than 25 countries since the first surgery in France 19 years ago. In 2013, Mobi-C became the first cervical disc to win approval from ... May 01, 2019. SAN DIEGO — Improvements were sustained at 10 years for patients treated with the Mobi-C cervical disc in the trial that led to its approval by the US Food and Drug Administration ...The Mobi-C ® Cervical Disc Prosthesis is indicated in skeletally mature patients for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy (arm pain and/or a neurological deficit) with or without neck pain, or myelopathy due to abnormality localized to the level of the disc space and at least one of the following ...As a potential candidate for cervical disc replacement, ZimVie offers the Mobi-C Reimbursement Services Program. This service is intended to help establish coverage with commercial insurers who are not currently covering Mobi-C for one or two levels. Contact the ZimVie Mobi-C reimbursement hotline 877-331-0062 and [email protected] for assistance.Zimmer Biomet Spine has announced that over 150,000 Mobi-C Cervical Discs have been implanted worldwide. The implant, a cobalt chromium alloy and polyethylene mobile-bearing prosthesis, was first implanted in France in 2004 and was approved for sale in the U.S. by the FDA in 2013. Noting the bulwark of data on the device, James Cloar, President ...The Mobi-C Cervical Disc (Zimmer Biomet, Warsaw, IN—formerly LDR Spine, Austin, TX) is a cobalt chromium alloy and polyethylene mobile-bearing prosthesis that is indicated for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy in patients ages 21 to 67 years.²The Mobi-C® Cervical Disc is indicated in skeletally mature patients for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy (arm pain and/or a neurological deficit) with or without neck pain,Results: There was no statistical significance in the difference of overall flexion range between M6-C and Mobi-C prostheses. However, overall range of extension of Mobi-C was greater compared to M6-C (P = 0.028). At C 5-6, the range of flexion for both implants were similar but lesser compared to asymptomatic patients (P < 0.001). Range of ...Mobi-C’s foundation is the patented mobile core, which offers controlled mobility and encourages height restoration. The components of Mobi-C include superior and inferior Cobalt Chromium alloy endplates coated with plasma sprayed Titanium and hydroxyapatite coating, and a polyethylene mobile bearing insert.Nov 17, 2016 · The Mobi-C Cervical Disc (Zimmer Biomet, Warsaw, IN—formerly LDR Spine, Austin, TX) is a cobalt chromium alloy and polyethylene mobile-bearing prosthesis that is indicated for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy in patients ages 21 to 67 years.² Sep 27, 2019 · Mobi-C group composed of 15 subjects, in which 6 were male and 9 were female. There were no statistical differences in demographics and baseline characteristics of subjects between the M6-C and Mobi-C groups, including age, gender, BMI, smoking history, the type of surgery, ROM and FSU height ( Table 7 ). Mar 28, 2018 · Mobi-C Cervical Disc Mobi-C is the first cervical disc prosthesis approved by the FDA for reconstruction of a cervical disc at both one and two levels (C3-C7). Mobi-C is a cobalt chromium alloy and polyethylene mobile-bearing prosthesis that is inserted in a single step, without requiring bone chiseling to accommodate vertebral anchorage such as screws or keels. Mobi-C® Cervical Disc. The upper and lower bone-facing endplates of the Mobi-C® Cervical Disc are made of a cobalt chromium molybdenum alloy. The endplates are coated with a fine layer of titanium and hydroxyapatite to promote integration with bone.Methods: This was a prospective study of patients treated with CDA at 1 or 2 contiguous levels using the Mobi-C® Cervical Disc (Zimmer Biomet). Following completion of the 7-yr Food and Drug Administration postapproval study, follow-up continued to 10 yr for consenting patients at 9 high-enrolling centers.This is a surgical video of a cervical disc replacement with the Zimmer Biomet Mobi-C TDR for treatment of a large C5-6 extruded disc herniation resulting in...The Mobi-C Cervical Disc has been designed for cervical disc replacement to restore segmental motion and disc height. TrellOss ®- C Porous Ti Interbody System TrellOss-C is an additively manufactured spacer for implantation up to two levels in the cervical spine. Mobi-C provides bone sparing fixation without chisel cuts into the small vertebral bodies of the cervical spine, making it safe for implantation at two levels. About Mobi-C Disc Replacement Mobi-C Disc Replacement is performed under general anesthesia, usually as an outpatient procedure. The replacement Mobi-C device has not failed to date, unlike the first Mobi-C device, which failed 1 week postoperatively in this same patient. This result likely rules out patient factors as the underlying cause of failure and may speak to the increased need to have a very precise surgical technique to prevent anterior slippage of the endplate ...The Mobi-C disc is one of the most common options for replacement cervical discs around the world. The medical device was first used in 2004 and has continued to be used successfully in patients with cervical disc issues (that is, disc issues in the neck). Without a doubt, many people who have undergone a Mobi-C disc procedure have had ...Mobi-C Had Lower Rates of Adjacent Segment Degeneration at 84 Months Mobi-C Had Fewer Subsequent Surgeries at 84 Months The ONE-LEVEL deterioration of adjacent segments at 84 months compared to baseline was: • 43.8% for Mobi-C compared to 63.0% for ACDF at the inferior level. • 40.4% for Mobi-C compared to 65.1% for ACDF Zimmer Biomet Spine has announced that over 150,000 Mobi-C Cervical Discs have been implanted worldwide. The implant, a cobalt chromium alloy and polyethylene mobile-bearing prosthesis, was first implanted in France in 2004 and was approved for sale in the U.S. by the FDA in 2013. Noting the bulwark of data on the device, James Cloar, President ...Mobi-C® Cervical Disc. The upper and lower bone-facing endplates of the Mobi-C® Cervical Disc are made of a cobalt chromium molybdenum alloy. The endplates are coated with a fine layer of titanium and hydroxyapatite to promote integration with bone.The following conclusions can be drawn from the present study review: 1) one-level Mobi-C CDA is non-inferior, but not superior, to one-level ACDF for patients with cervical DDD; 2) the Mobi-C CDA procedure is associated with high rates of HO; and 3) two-level Mobi-C CDA may be superior to two-level ACDF, but substantial evidence is lacking ...Ethical standards: The Mobi-C Clinical Trial (ClinicalTrials.gov registration number: NCT00389597) was conducted at 24 sites in the US and was approved by the Institutional Review Board, Research Ethics Committee, or local equivalent of each participating site. Level of evidence: 1.Mobi-C Cervical Disc is an FDA approved artificial cervical disc for one and two level disc replacement and helps those with degenerative disc disease maintain neck mobility. Unlike fusion procedures, Mobi-C implants fits entirely within the disc space and attempts to maintain neck movement.The Mobi-C differs from some other contemporary disc designs in that it has a mobile polyethylene insert that is sandwiched between superior and inferior cobalt chromium endplates. While some studies claim the Mobi-C to have restored normal cervical spinal biomechanics, others have noted high levels of migration.Nov 17, 2016 · The Mobi-C Cervical Disc (Zimmer Biomet, Warsaw, IN—formerly LDR Spine, Austin, TX) is a cobalt chromium alloy and polyethylene mobile-bearing prosthesis that is indicated for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy in patients ages 21 to 67 years.² Results: There was no statistical significance in the difference of overall flexion range between M6-C and Mobi-C prostheses. However, overall range of extension of Mobi-C was greater compared to M6-C (P = 0.028). At C 5-6, the range of flexion for both implants were similar but lesser compared to asymptomatic patients (P < 0.001). Range of ... The Mobi-C ® Cervical Disc Prosthesis is indicated in skeletally mature patients for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy (arm pain and/or a neurological deficit) with or without neck pain, or myelopathy due to abnormality localized to the level of the disc space and at least one of the following ...LDR Spine –Mobi-C® P110009 Page 3 of 82 The Mobi-C® endplates are available in seven footprint sizes to address individual patient anatomy and maximize endplate coverage. These sizes are illustrated in the table below. Table 1. Mobi-C® Device Configurations Depth x Width (mm) Inferior/Superior Plate & Mobile Insert Sizes Combinations ... Aug 28, 2020 · The objective is to report a case of an early dislocation of Mobi-C prosthesis used for the replacement of C4–C5 disc. A 57-year-old man who was operated 17 years before for C6–C7 fusion complained of cervicalgia associated with bilateral but predominantly right-sided brachialgia. Magnetic resonance imaging demonstrated central and ... About this app. Mobile trade support system "Mobi-S" is a software package designed to automate the work of sales representatives. Automate order picking, wheel trading and collecting merchandising information. Easy integration with the main configurations of 1C Enterprise 8.2, 8.3 and 7.7. There is everything you need to collect applications ...The Mobi-C Cervical Disc is now available to more than 200 million insured patients with one-level disc disease and more than 150 million patients with two-level disc disease across more than 90 commercial insurance plans. That makes Mobi-C the most widely covered intervertebral disc for cervical disc replacement in the industry.The Mobi-C Cervical Disc has been designed for cervical disc replacement to restore segmental motion and disc height. TrellOss ®- C Porous Ti Interbody System TrellOss-C is an additively manufactured spacer for implantation up to two levels in the cervical spine.Zimmer Biomet Spine has announced that more than 150,000 Mobi-C Cervical Discs have been implanted worldwide. Zimmer Biomet holds a commanding position in the $200 million global cervical disc market, according to the company. The Mobi-C device represents an optimal solution with statistical superiority to two-level fusion at seven years.Results: There was no statistical significance in the difference of overall flexion range between M6-C and Mobi-C prostheses. However, overall range of extension of Mobi-C was greater compared to M6-C (P = 0.028). At C 5-6, the range of flexion for both implants were similar but lesser compared to asymptomatic patients (P < 0.001). Range of ...The Mobi-C cervical disc is one of the most widely used cervical discs in the world. Mobi-C contains patented Mobile Core Technology™ that allows the polyeth...Zip. Institution. Map. Details. Email These Surgeons to Me. Zimmer Biomet is pleased to provide the Surgeon Locator to allow you to find surgeons who have been trained on Mobi-C. This locator may not be a complete list of trained surgeons in your area, and Zimmer Biomet does not make any recommendation or referral regarding the proper facility ...Mobi-C – How it Works. Mobi-C contains patented mobile bearing technology that allows the polyethylene core to slide and rotate inside the disc for self-adjustment to the cervical spine movements. This means that Mobi-C can react to the normal motion in the cervical spine. Mar 23, 2016 · The Mobi-C cervical disc is one of the most widely used cervical discs in the world. Mobi-C contains patented Mobile Core Technology™ that allows the polyeth... The Mobi-C disc is one of the most common options for replacement cervical discs around the world. The medical device was first used in 2004 and has continued to be used successfully in patients with cervical disc issues (that is, disc issues in the neck). Without a doubt, many people who have undergone a Mobi-C disc procedure have had ... Mobi-C provides bone sparing fixation without chisel cuts into the small vertebral bodies of the cervical spine, making it safe for implantation at two levels. About Mobi-C Disc Replacement Mobi-C Disc Replacement is performed under general anesthesia, usually as an outpatient procedure.Sep 7, 2022 · 1. "Looks like the Mobi-C failed, replace it with a ProDisc or try a fusion without a plate at one level. Unclear of which approach would be best", recommended me to a specialist in ADR more verse in this case. (Orthopedic Spine surgeon from TN) 2. Surgeon that was referred to me by the above. "Mobi-C failed, causing instability and hypermobility. Mobi-C Cervical Disc is an artificial disc that can replace a worn or degenerative disc. This surgery helps provide both lateral and vertical range of motion along with maintaining neck rotation. This differs from spinal fusion surgery when two of the vertebrae are fused together with hardware, which constricts the neck’s range of motion. Apr 3, 2023 · Mobi-C is a cobalt chromium alloy and polyethylene mobile-bearing prosthesis that is inserted in a single step, without requiring bone chiseling or other vertebral anchorage such as screws or keels. Dec 1, 2022 · Page 1 of 7 Last Updated 01-DECEMBER-2022 . Zimmer Biomet Patent Marking . This information is provided as notice of patented articles pursuant to 35 U.S.C. § 287(a). Apr 1, 2019 · Product Usage: The device is intended as a cervical intervertebral disc replacement at one or two contiguous levels from C3 to C7 designed to maintain/restore segmental motion and disc height. MOBI-C distraction pins are inserted into the vertebral body below and above the disc that is to have the disc replacement. An infection at the surgery site, such as a skin rash or infected cut. A known allergy to what Mobi-C is made of: cobalt, chromium, molybdenum, titanium, hydroxyapatite, polyethylene, and other trace elements. Talk to your doctor if you have a metal allergy. Damaged cervical vertebrae from an accident (trauma) at one of the surgery levels. Mobi-C Cervical Disc Mobi-C is the first cervical disc prosthesis approved by the FDA for reconstruction of a cervical disc at both one and two levels (C3-C7). Mobi-C is a cobalt chromium alloy and polyethylene mobile-bearing prosthesis that is inserted in a single step, without requiring bone chiseling to accommodate vertebral anchorage such as screws or keels.LDR Spine –Mobi-C® P110009 Page 3 of 82 The Mobi-C® endplates are available in seven footprint sizes to address individual patient anatomy and maximize endplate coverage. These sizes are illustrated in the table below. Table 1. Mobi-C® Device Configurations Depth x Width (mm) Inferior/Superior Plate & Mobile Insert Sizes Combinations ... In a surgery with the Mobi-C Cervical Disc, the unhealthy disc is removed, but instead of a bone spacer or plastic implant along with a plate and screws, a Mobi-C is implanted into the disc space. Where a fusion procedure is intended to eliminate motion at the surgery levels, the goal of a surgery with Mobi-C is to allow motion at those levels. The Mobi-C has three parts: two metal plates and a medical grade polyethylene insert in the middle. The top plate rotates over the domed insert. The insert slides across the bottom plate, left-to-right and front-to-back up to 1mm in any direction. The insert also twists over the bottom plate. The two tabs on the bottom plate provide a safety ...Restoring natural motion to the cervical spine. The controlled mobility of the patented mobile core is the foundation of Mobi-C. With vertebrae and neck muscle movement, the Mobi-C implant is free to twist and slide left-to-right, and front-to-back, as well as rotate.The Mobi-C Cervical Disc is implanted using an anterior approach. Patients should have failed at least 6 weeks of conservative treatment or demonstrated progressive signs or symptoms despite nonoperative treatment prior to implantation of the Mobi-C Cervical Disc. Physician CPT® Code CPT Description Insertion 22856However, Mobi-C disc replacement is very different in a number of ways. The purpose of the replacement surgery is obviously to replace the damaged disc and help with neck pain, arm pain, and arm tingling, for instance. However, the device is designed to promote neck movement (including turning left-to-ride, bending side-to-side, and bending ...Results: There was no statistical significance in the difference of overall flexion range between M6-C and Mobi-C prostheses. However, overall range of extension of Mobi-C was greater compared to M6-C (P = 0.028). At C 5-6, the range of flexion for both implants were similar but lesser compared to asymptomatic patients (P < 0.001). Range of ...The Mobi-C Cervical Disc is one of the most widely used cervical discs in the world. First implanted in France in November 2004, Mobi-C has now been implanted in more than 75,000 spinal levels in 25 countries. Mobi-C is intended for adult patients (skeletally mature) with arm pain and/or neurological symptoms (such as weakness or numbness) with ...Mobi-C implant surgery is a safe alternative to ACDF surgery in cervical disc degeneration. Cite this article: Bone Joint J 2016;98-B:829-3. Effectiveness and safety of Mobi-C for treatment of single-level cervical disc spondylosis: a randomised control trial with a minimum of five years of follow-up Zimmer Biomet Spine has announced that more than 150,000 Mobi-C Cervical Discs have been implanted worldwide. Zimmer Biomet holds a commanding position in the $200 million global cervical disc market, according to the company. The Mobi-C device represents an optimal solution with statistical superiority to two-level fusion at seven years.Mobi-C is a safe and effective surgical option at one-level in the cervical spine from C3-C7 for indicated patients. The controlled mobility of the Mobi-C’s mobile insert, according to the company's website for Chinese surgeons, encourages restoration and respect of the instantaneous axis of rotation for a return to physiological mobility of ...Two-level CDA with the Mobi-C® device demonstrated equivalent, and in certain aspects, favorable outcomes compared to ACDF for treatment of symptomatic cervical 2-level degenerative disc disease (DDD) indicating a satisfactory safety and efficacy profile. Two-level CDA with the Mobi-C® device demonstrated equivalent, and in certain aspects, favorable outcomes compared to ACDF for treatment of symptomatic cervical 2-level degenerative disc disease (DDD) indicating a satisfactory safety and efficacy profile.The average return to work time was 20.9 days shorter for Mobi-C compared to ACDF. The patients in this study will continue to be followed for 7 years after surgery. The clinical benefit beyond five years has not been measured. To find a trained Mobi-C surgeon, please visit the surgeon locator. Potential adverse effects from surgery with the Mobi-C Zimmer Biomet Spine has announced that more than 150,000 Mobi-C Cervical Discs have been implanted worldwide. Zimmer Biomet holds a commanding position in the $200 million global cervical disc market, according to the company. The Mobi-C device represents an optimal solution with statistical superiority to two-level fusion at seven years.MOBI-C® prosthesis is a device for cervical intervertebral disc replacement (C3/C4, C4/C5, C5/C6, C6/C7) in order to restore segmental motion and disc height. Before any surgical procedure, read carefully the instructions and the surgical technique. Open the catalog to page 1. SURGICAL TECHNIQUE Pre-operative considerations Implant height ...What is Mobi-C. Mobi-C is the first cervical disc in the U.S. approved to treat more than one level of the cervical spine. It received FDA approval for one and two-level indications in August 2013. Mobi-C demonstrated statistical superiority compared to cervical spine fusion in overall study success when used in two-level patients at 5 years.Mobi-C Prestige ST Prodisc C 26 Lumbar ADR 22857 Total disc arthroplasty (artificial disc), anterior approach, including discectomy to prepare interspace (other than for decompression), single interspace, lumbar 0163T each additional interspace, lumbar (List separatelyMobi-C – How it Works. Mobi-C contains patented mobile bearing technology that allows the polyethylene core to slide and rotate inside the disc for self-adjustment to the cervical spine movements. This means that Mobi-C can react to the normal motion in the cervical spine.The Mobi-C Cervical Disc has been designed for cervical disc replacement to restore segmental motion and disc height. The components of Mobi-C include superior and inferior cobalt chromium molybdenum alloy endplates coated with plasma sprayed titanium and hydroxyapatite coating, and a polyethylene mobile bearing insert. Ethical standards: The Mobi-C Clinical Trial (ClinicalTrials.gov registration number: NCT00389597) was conducted at 24 sites in the US and was approved by the Institutional Review Board, Research Ethics Committee, or local equivalent of each participating site. Level of evidence: 1.One limitation of this study was the specific inclusion and exclusion criteria for entry into the study. At the time of conception, the intention of the Mobi-C study was to enroll patients without significant conditions that could confound the outcome of an artificial disc.The Mobi-C device was thought by the plaintiff to be flawed since it differed from the device that the Food and Drug Administration had approved, which affect the “safety and efficacy of the ...Oct 27, 2016 · The Mobi-C Cervical Disc is now available to more than 200 million insured patients with one-level disc disease and more than 150 million patients with two-level disc disease across more than 90 commercial insurance plans. That makes Mobi-C the most widely covered intervertebral disc for cervical disc replacement in the industry. The Mobi-C Cervical Disc is implanted using an anterior approach. Patients should have failed at least 6 weeks of conservative treatment or demonstrated progressive signs or symptoms despite nonoperative treatment prior to implantation of the Mobi-C Cervical Disc. Physician CPT® Code CPT Description Insertion 22856Mobi-C Prestige ST Prodisc C 26 Lumbar ADR 22857 Total disc arthroplasty (artificial disc), anterior approach, including discectomy to prepare interspace (other than for decompression), single interspace, lumbar 0163T each additional interspace, lumbar (List separatelyJan 30, 2023 · Mobi-C is a cobalt chromium alloy and polyethylene mobile-bearing prosthesis that is inserted in a single step, without requiring bone chiseling or other vertebral anchorage such as screws or keels. The primary objective of this study was to rigorously compare the Mobi-C cervical artificial disc to ACDF for treatment of cervical DDD at 2 contiguous levels of the cervical spine. Methods: This study was a prospective, randomized, US FDA investigational device exemption pivotal trial of the Mobi-C cervical artificial disc conducted at 24 ... Mobi-C Had Lower Rates of Adjacent Segment Degeneration at 84 Months Mobi-C Had Fewer Subsequent Surgeries at 84 Months The ONE-LEVEL deterioration of adjacent segments at 84 months compared to baseline was: • 43.8% for Mobi-C compared to 63.0% for ACDF at the inferior level. • 40.4% for Mobi-C compared to 65.1% for ACDFMay 18, 2023 · About this app. Mobile trade support system "Mobi-S" is a software package designed to automate the work of sales representatives. Automate order picking, wheel trading and collecting merchandising information. Easy integration with the main configurations of 1C Enterprise 8.2, 8.3 and 7.7. There is everything you need to collect applications ... Cervical disc replacement surgery is designed to replace a damaged spinal disc in the neck with an artificial disc implant. Damaged cervical discs are most likely to occur at the C4-C5, C5-C6, or C6-C7 levels.The Mobi-C® Cervical Disc is indicated in skeletally mature patients for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy (arm pain and/or a neurological deficit) with or without neck pain,Mobi C Artificial Disc New research studies by the North American Spine Society — the most respected international society of spine surgeons — have shown that when a person has a herniated disc in the neck, and traditional fusion surgery is performed, there is an increased incidence of herniation at an adjacent segment.Dr. Louis Radden is offering an alternative to neck fusion surgery, and is one of a few surgeons in Michigan to perform this breakthrough procedure. Mobi-C Cervical Disc was FDA approved for use in the United States in 2013 and to date has been used worldwide in over 40,000 procedures with superb results. It is also the first cervical disc ... Mobi-C provides bone sparing fixation without chisel cuts into the small vertebral bodies of the cervical spine, making it safe for implantation at two levels. About Mobi-C Disc Replacement Mobi-C Disc Replacement is performed under general anesthesia, usually as an outpatient procedure. • A single Mobi-C prosthesis costs £1,750 (excluding VAT). Two Mobi-C devices are needed for 2-level cervical disc replacement. • A US cost-effectiveness analysis found that the average cost per patient in the 5 years after surgery was $23,459 (about £16,515) for Mobi-C, and $21,772 (about £16,031) for ACDF.

Mobi-C implant surgery is a safe alternative to ACDF surgery in cervical disc degeneration. Cite this article: Bone Joint J 2016;98-B:829-3. Effectiveness and safety of Mobi-C for treatment of single-level cervical disc spondylosis: a randomised control trial with a minimum of five years of follow-up . Boob

mobi c

However, Mobi-C disc replacement is very different in a number of ways. The purpose of the replacement surgery is obviously to replace the damaged disc and help with neck pain, arm pain, and arm tingling, for instance. However, the device is designed to promote neck movement (including turning left-to-ride, bending side-to-side, and bending ... Two-level CDA with the Mobi-C® device demonstrated equivalent, and in certain aspects, favorable outcomes compared to ACDF for treatment of symptomatic cervical 2-level degenerative disc disease (DDD) indicating a satisfactory safety and efficacy profile.The Mobi-C has three parts: two metal plates and a medical grade polyethylene insert in the middle. The top plate rotates over the domed insert. The insert slides across the bottom plate, left-to-right and front-to-back up to 1mm in any direction. The insert also twists over the bottom plate. The two tabs on the bottom plate provide a safety ... Mobi-C is non-inferior to ACDF at one level and superior at two levels2 Mobi-C had lower rates of adjacent segment degeneration at 84 months Mobi-C had fewer subsequent surgeries at 84 months One-level deterioration of adjacent segments at 84 months compared to baseline: • 43.8% for Mobi-C compared to 63.0% for ACDF at the inferior level. It turns out that somewhere between 30% and 50% of patients who are candidates for a fusion are good candidates for a Mobi-C.” Study May Improve Insurance Coverage of the Mobi-C “In general, the Mobi-C is not more expensive than fusion surgery, but insurers have still been slow to embrace this new technology,” Dr. Hisey said.Zimmer Biomet Spine has announced that over 150,000 Mobi-C Cervical Discs have been implanted worldwide. The implant, a cobalt chromium alloy and polyethylene mobile-bearing prosthesis, was first implanted in France in 2004 and was approved for sale in the U.S. by the FDA in 2013. Noting the bulwark of data on the device, James Cloar, President ...• A single Mobi-C prosthesis costs £1,750 (excluding VAT). Two Mobi-C devices are needed for 2-level cervical disc replacement. • A US cost-effectiveness analysis found that the average cost per patient in the 5 years after surgery was $23,459 (about £16,515) for Mobi-C, and $21,772 (about £16,031) for ACDF.Results: There was no statistical significance in the difference of overall flexion range between M6-C and Mobi-C prostheses. However, overall range of extension of Mobi-C was greater compared to M6-C (P = 0.028). At C 5-6, the range of flexion for both implants were similar but lesser compared to asymptomatic patients (P < 0.001). Range of ...In a surgery with the Mobi-C Cervical Disc, the unhealthy disc is removed, but instead of a bone spacer or plastic implant along with a plate and screws, a Mobi-C is implanted into the disc space. Where a fusion procedure is intended to eliminate motion at the surgery levels, the goal of a surgery with Mobi-C is to allow motion at those levels.The Mobi-C Cervical Disc has been designed for cervical disc replacement to restore segmental motion and disc height. The components of Mobi-C include superior and inferior cobalt chromium molybdenum alloy endplates coated with plasma sprayed titanium and hydroxyapatite coating, and a polyethylene mobile bearing insert. It turns out that somewhere between 30% and 50% of patients who are candidates for a fusion are good candidates for a Mobi-C.” Study May Improve Insurance Coverage of the Mobi-C “In general, the Mobi-C is not more expensive than fusion surgery, but insurers have still been slow to embrace this new technology,” Dr. Hisey said.Mar 23, 2016 · The Mobi-C cervical disc is one of the most widely used cervical discs in the world. Mobi-C contains patented Mobile Core Technology™ that allows the polyeth... The Mobi-C® Cervical Disc is indicated in skeletally mature patients for reconstruction of the disc from C3-C7 following discectomy at one level or two contiguous levels for intractable radiculopathy (arm pain and/or a neurological deficit) with or without neck pain,Dec 1, 2022 · Page 1 of 7 Last Updated 01-DECEMBER-2022 . Zimmer Biomet Patent Marking . This information is provided as notice of patented articles pursuant to 35 U.S.C. § 287(a). In 2015, FDA approved an update to the Mobi-C labeling to include five year clinical results. Of note, Mobi-C demonstrated superiority at all time points to five years on overall trial success as compared to two-level ACDF. The Mobi-C consists of two cobalt chromium (CoCr) endplates that are plasma sprayed with titaniumMobi-C – How it Works. Mobi-C contains patented mobile bearing technology that allows the polyethylene core to slide and rotate inside the disc for self-adjustment to the cervical spine movements. This means that Mobi-C can react to the normal motion in the cervical spine. Mobi-C Prestige ST Prodisc C 26 Lumbar ADR 22857 Total disc arthroplasty (artificial disc), anterior approach, including discectomy to prepare interspace (other than for decompression), single interspace, lumbar 0163T each additional interspace, lumbar (List separately.

Popular Topics